Brand Name : MEAN WELL
Model Number : MDR-10-5
Certification : CE
Place of Origin : CN
MOQ : 1 piece
Price : 1 USD
Payment Terms : L/C,T/T
Supply Ability : 3000 pieces per month
Delivery Time : 8-10 weeks
Packaging Details : cartons
Brand : MEAN WELL
Product Namee : DIN RAIL
Output currency : 2,4A-0.32A
Rated power : 12W -15.4W
Input frequency : 47 ~ 63Hz
DC voltgae : 5V-24V
Efficiency : 77% -84%
Protection : over voltgae / over load
Dimension : 22.5*90*100mm (W*H*D)
Weight : 0.15kg
Mean Well Brand MDR-10-5 DIN RAIL MDR-20 MDR-40 MDR-60 MDR-100
Mean Well MDR-10-5 DIN RAIL MDR-20 MDR-40 MDR-60 MDR-100
Plastic case, ultra slim
1∅, full range input
No load power consumption<0.75W~1W
Assemble on industrial rail TS-35 / 7.5 or 15
Built-in active PFC function
Class I, Div 2 Hazardous Locations T4 (MDR-40/60)
Technical
MODEL | MDR-10-5 | MDR-10-12 | MDR-10-15 | MDR-10-24 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V |
RATED CURRENT | 2A | 0.84A | 0.67A | 0.42A | |
CURRENT RANGE | 0 ~ 2A | 0 ~ 0.84A | 0 ~ 0.67A | 0 ~ 0.42A | |
RATED POWER | 10W | 10W | 10W | 10W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±5.0% | ±3.0% | ±3.0% | ±2.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±5.0% | ±3.0% | ±3.0% | ±2.0% | |
SETUP, RISE TIME Note.5 | 500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 120ms/230VAC 25ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY (Typ.) | 77% | 81% | 81% | 84% | |
AC CURRENT (Typ.) | 0.33A/115VAC 0.21A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 35A/115VAC 70A/230VAC | ||||
LEAKAGE CURRENT | <1mA / 240VAC | ||||
PROTECTION | OVERLOAD | Above 105% rated output power | |||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||
FUNCTION | DC OK ACTIVE SIGNAL (max.) | 3.75 ~ 6V / 50mA | 9 ~ 13.5V / 40mA | 11.5 ~ 16.5V / 40mA | 18 ~ 27V / 20mA |
ENVIRONMENT | WORKING TEMP. | -20 ~ +70℃ (Refer to "Derating Curve") | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | ||||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL508, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI CNS14336-1, AS/NZS 62368.1 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B | ||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55024,BS EN/EN61000-6-1,BS EN/EN61204-3, light industry level, EAC TP TC 020 | ||||
OTHERS | MTBF | 3334.7K hrs min. Telcordia SR-332 (Bellcore) ; 584.0K hrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 22.5*90*100mm (W*H*D) | ||||
PACKING | 0.15Kg; 72pcs/11.8Kg/1.04CUFT | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |